Instrumentation and Controls, Inc

Instrumentation and Controls, Inc

  • 100 Industrial Dr
  • Doylestown, Pennsylvania
  • 18901-5191

Description

Traceable Calibrations We offer calibrations that are traceable to a national standard. Calibrations are performed by Outside . Work can be done at our facility, or on your site. ICI has documented calibration procedures (SOP’s). ICI provides documentation to support the calibrations. All calibrations are traceable to NIST. Each technician is issued a log book. The log book becomes a controlled document. All calibration data is recorded in the log book. The technician then enters the log book data into a computer data base. A calibration sheet is then printed and reviewed by the technician. After verifying that the data was transferred correctly, the technician places his signature on the sheet. This Original Signature document becomes the calibration turnover document. All original signature documents are placed in a binder which is separated by tab sets that are identified by instrument tag number. This Original Signature binder becomes the calibration turnover document. Documentation and documentation control is paramount at ICI. All of the work we perform is linked together in a common data base. This commonality allows us to: - Retrieve the documents that support the technicians training and certification. - Print a list of all test equipment assets that were used on a given project. - Retrieve the NIST traceable documents to support the test standards used on your project. - Out of tolerance test equipment - the data base allows us to quickly identify which client instruments would be affected by an ICI asset that was found to be out of tolerance. Via the data base, a list sorted by client could be generated showing us where each affected piece is located. - That client is notified of the out of tolerance condition by way of an ICI out of tolerance report. Accompanying this report is a more extensive report which contains error data. With this information, a client can access if the out of tolerance condition was significant enough to affect their final product. Instrumentation and Controls, Incorporated has over one million dollars invested in state of the art test equipment. Pressure On the low end. our technicians can execute a five point calibration in the range of -.25 to + .25 inches of water with accuracy that will exceed the accuracy statement on the calibrated instrument. On the high end, we can give you five points over 0 to 20000 psig. Humidity Our traceable humidity standard can be used where 1% accuracy is required. Other instruments There is virtually no instrument that we can not perform a traceable calibration on.

Products & services

Similar companies nearby